1. HT/LT Electrical Works & Power Infrastructure
The backbone of every data center is its power feed — and Ujjwal Shilp executes the complete high and low tension electrical infrastructure from the utility connection point to every rack PDU. Scope covers HT metering cubicles, power transformers, main LT switchgear (MLDB), bus ducts, sub-distribution panels, and dedicated UPS feeder circuits — sized and installed for N+1 redundancy.
Key capabilities:
- HT cable laying and termination (11 kV, 33 kV)
- Dry-type and oil-filled transformer installation (up to 5 MVA)
- MLDB / PDB (Power Distribution Board) erection and wiring
- Bus duct installation (sandwich bus trunking)
- Cable tray and cable ladder systems
- HT/LT metering panel installation
- Earthing and lightning protection systems (IS 3043)
- Power quality analyser and energy meter installation
2. UPS Systems & Critical Power Works
Uninterruptible power supply infrastructure is the most critical element in a data center — zero tolerance for failure. Ujjwal Shilp installs, commissions, and maintains static online UPS systems, battery rooms, and automatic static transfer switches (STS) for N, N+1, and 2N redundancy configurations as per customer's Tier specification.
Key capabilities:
- Online UPS installation (10 kVA to 2,000 kVA single/parallel units)
- VRLA and Li-ion battery bank installation and commissioning
- Battery room civil works — acid-resistant flooring, ventilation, spill containment
- Static Transfer Switch (STS) installation for dual-bus configurations
- PDU (Power Distribution Unit) installation at rack level
- UPS bypass panel and maintenance bypass works
- Battery monitoring system (BMS) wiring and commissioning
- Annual maintenance contracts for UPS and battery systems
3. Precision Cooling & HVAC MEP Works
Data centers generate intense thermal loads that demand specialised cooling infrastructure — CRAC/CRAH units, in-row cooling, chilled water systems, and hot/cold aisle containment. Ujjwal Shilp handles the full MEP scope for precision cooling, from chilled water piping to electrical works for cooling equipment, ensuring the facility maintains sub-25°C ambient temperatures at rated IT load.
Key capabilities:
- Computer Room Air Conditioning (CRAC/CRAH) unit installation
- Chilled water piping (CPVC/GI) for air handling units
- In-row cooling unit placement and connection
- Hot aisle/cold aisle containment — structural and civil works
- Precision AC electrical connections (3-phase, dedicated circuits)
- Cooling tower and chiller plant civil works
- Condensate drain piping works
- BMS (Building Management System) sensor wiring
4. Civil & Raised Floor Works
The physical infrastructure of a data center — its civil shell, raised access floor, walls, and containment architecture — defines the long-term reliability of the facility. Ujjwal Shilp executes the complete civil scope from RCC structural works, anti-static raised floor installation, and partition systems to fire-rated wall sealing, cable entry points, and access control civil provisions.
Key capabilities:
- Anti-static raised access floor (600×600 mm panels, heights 300–600 mm)
- False ceiling works — grid ceiling and GI framing
- Partition walls — gypsum board and fire-rated systems
- Cable entry sealing (fire-rated intumescent seals)
- Equipment plinth and foundation works for generators and transformers
- Epoxy/anti-static floor coatings for server halls
- Blast-proof and EMI-shielded room construction
- Civil works for generator yards, transformer bays, cooling plant areas
5. DG Sets & Fuel Systems — Critical Power Backup
Mains power failure is unacceptable in data centers. Diesel generator sets provide the last line of backup defence — and Ujjwal Shilp handles complete DG installation including civil foundations, acoustic enclosures, AMF panels, synchronisation panels for parallel operation, exhaust systems, and bulk fuel storage.
Key capabilities:
- DG set installation (62.5 kVA to 3,000 kVA, Cummins / Kirloskar / Caterpillar)
- Civil foundation and inertia block construction for gensets
- Acoustic enclosure and exhaust silencer installation
- AMF (Automatic Mains Failure) panel works
- Synchronising panels for parallel DG operation
- HSD bulk fuel tank (FRP/MS) installation with bund wall
- Day tank and fuel transfer pump piping works
- Exhaust piping (acoustic-grade SS/GI) to roof level
- Load bank testing and commissioning
6. Structured Cabling & Network Infrastructure
A well-designed structured cabling system ensures the physical layer of your data center network is clean, manageable, and future-ready. Ujjwal Shilp installs certified Cat6A / Cat7 copper and OS2 fibre optic cabling systems with full cable management, rack infrastructure, and labelling — meeting TIA-942 and ISO/IEC 24764 standards for data centers.
Key capabilities:
- Cat6A (10G) structured cabling — server-to-TOR switch runs
- OS2 single-mode and OM4 multi-mode fibre optic cabling
- Fibre splicing and OTDR testing
- Cable tray (perforated/ladder) and containment routing
- Open-frame and enclosed rack installation (19" / 23")
- Patch panel and keystone jack termination
- Comprehensive labelling and documentation (as-built drawings)
- Cable testing certification — Fluke DTX / DSP test reports
Compliance & Standards We Work To
| Standard |
Scope |
| TIA-942 / Uptime Institute |
Tier-II and Tier-III MEP design compliance |
| NBC 2016 + SP 7 |
Civil and building services works |
| IE Act + CEA Regulations |
HT/LT electrical installation |
| IS 3043:2018 |
Earthing system design and installation |
| ASHRAE TC 9.9 |
Thermal management and cooling envelope |
| NFPA 75 / IS 15526 |
Fire protection for IT equipment areas |
Why Choose Ujjwal Shilp for Data Center Works
- Single-vendor MEP — civil, HT/LT electrical, cooling, cabling from one contractor. No coordination gaps, no blame-shifting between trades.
- Mission-critical experience — executed MEP works for STPI centres, enterprise server rooms, and hospital-grade critical infrastructure.
- Commissioning-ready teams — our engineers carry out pre-commissioning, functional testing, and handover documentation before sign-off.
- Active in emerging hubs — present in Bihar (Darbhanga STPI, Patna), Siliguri, and Delhi NCR — regions seeing fast data center growth.
- Post-handover AMC — 24×7 breakdown response and annual maintenance contracts available for all MEP systems.